Technical specifications

Number of poles3
Number of auxiliary contacts as change-over contact0
Adjustment range undelayed short-circuit release300 - 400A
Position of connection for main current circuitFront side
With switched-off indicatorNo
Overload release current setting28.0 - 40A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Number of auxiliary contacts as normally open contact0
Degree of protection (IP)IP20
Number of auxiliary contacts as normally closed contact0
Adjustment range short-term delayed short-circuit release- - -A
Motor drive integratedNo
Rated permanent current Iu160A
Rated voltage220 - 690V
Type of electrical connection of main circuitBolt connection
Type of control elementToggle
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device fixed built-in technique
With under voltage releaseNo
Motor drive optionalYes
Complete device with protection unitYes
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067598R1 | XT2H 160 TMA 40-400 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles

3

Number of auxiliary contacts as change-over contact

0

Adjustment range undelayed short-circuit release

300 .. 400A

Position of connection for main current circuit

Front side

With switched-off indicator

Overload release current setting

28.0 .. 40A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Number of auxiliary contacts as normally open contact

0

Degree of protection (IP)

IP20

Number of auxiliary contacts as normally closed contact

0

Adjustment range short-term delayed short-circuit release

- .. -A

Motor drive integrated

Rated permanent current Iu

160A

Rated voltage

220 .. 690V

Type of electrical connection of main circuit

Bolt connection

Type of control element

Toggle

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

With under voltage release

Motor drive optional

Complete device with protection unit

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.