Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release- - -A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Rated permanent current Iu160A
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalYes
With under voltage releaseNo
Suitable for DIN rail (top hat rail) mountingNo
Motor drive optionalYes
Complete device with protection unitYes
Motor drive integratedNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Adjustment range undelayed short-circuit release300 - 300A
Device constructionBuilt-in device fixed built-in technique
Number of poles4
Rated voltage220 - 690V
Type of electrical connection of main circuitBolt connection
Type of control elementToggle
Degree of protection (IP)IP20
Position of connection for main current circuitFront side
With switched-off indicatorNo
Overload release current setting14.0 - 20A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067616R1 | XT2H 160 TMD 20-300 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release

- .. -A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Rated permanent current Iu

160A

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

With under voltage release

Suitable for DIN rail (top hat rail) mounting

Motor drive optional

Complete device with protection unit

Motor drive integrated

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Adjustment range undelayed short-circuit release

300 .. 300A

Device construction

Built-in device fixed built-in technique

Number of poles

4

Rated voltage

220 .. 690V

Type of electrical connection of main circuit

Bolt connection

Type of control element

Toggle

Degree of protection (IP)

IP20

Position of connection for main current circuit

Front side

With switched-off indicator

Overload release current setting

14.0 .. 20A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.