Aleta.hr
Main Product Image

1SDA067616R1 | XT2H 160 TMD 20-300 4P F F

Code: 1530100

ManufacturerABB
Catalog number1SDA067616R1
Type
EAN code8015644015121

Details

  • Low-voltage control systems
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Adjustment range undelayed short-circuit release300 - 300A
Adjustment range short-term delayed short-circuit release- - -A
Overload release current setting14.0 - 20A
Integrated earth fault protectionNo
Degree of protection (IP)IP20
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as change-over contact0
Suitable for DIN rail (top hat rail) mountingNo
With switched-off indicatorNo
With under voltage releaseNo
DIN rail (top hat rail) mounting optionalYes
Device constructionBuilt-in device fixed built-in technique
Position of connection for main current circuitFront side
Type of control elementRocker lever
Complete device with protection unitYes
Motor drive integratedNo
Motor drive optionalYes
Rated permanent current Iu20A
Number of poles4
Rated voltage220 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067616R1 | XT2H 160 TMD 20-300 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage control systems
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Adjustment range undelayed short-circuit release

300 .. 300A

Adjustment range short-term delayed short-circuit release

- .. -A

Overload release current setting

14.0 .. 20A

Integrated earth fault protection

Degree of protection (IP)

IP20

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as change-over contact

0

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

With under voltage release

DIN rail (top hat rail) mounting optional

Device construction

Built-in device fixed built-in technique

Position of connection for main current circuit

Front side

Type of control element

Rocker lever

Complete device with protection unit

Motor drive integrated

Motor drive optional

Rated permanent current Iu

20A

Number of poles

4

Rated voltage

220 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA