Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu160A
Number of poles4
Overload release current setting44.1 - 63A
Number of auxiliary contacts as normally open contact0
Position of connection for main current circuitFront side
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Complete device with protection unitYes
Number of auxiliary contacts as change-over contact0
Motor drive optionalYes
Degree of protection (IP)IP20
DIN rail (top hat rail) mounting optionalYes
Adjustment range undelayed short-circuit release300 - 630A
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device fixed built-in technique
Motor drive integratedNo
With switched-off indicatorNo
Rated voltage220 - 690V
With under voltage releaseNo
Integrated earth fault protectionNo
Adjustment range short-term delayed short-circuit release- - -A
Type of control elementToggle
Type of electrical connection of main circuitBolt connection
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067621R1 | XT2H 160 TMA 63-630 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

160A

Number of poles

4

Overload release current setting

44.1 .. 63A

Number of auxiliary contacts as normally open contact

0

Position of connection for main current circuit

Front side

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Complete device with protection unit

Number of auxiliary contacts as change-over contact

0

Motor drive optional

Degree of protection (IP)

IP20

DIN rail (top hat rail) mounting optional

Adjustment range undelayed short-circuit release

300 .. 630A

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

Motor drive integrated

With switched-off indicator

Rated voltage

220 .. 690V

With under voltage release

Integrated earth fault protection

Adjustment range short-term delayed short-circuit release

- .. -A

Type of control element

Toggle

Type of electrical connection of main circuit

Bolt connection

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.