  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles3
Number of auxiliary contacts as normally closed contact0
Type of control elementToggle
Number of auxiliary contacts as normally open contact0
Degree of protection (IP)IP20
Position of connection for main current circuitFront side
Rated permanent current Iu160A
Number of auxiliary contacts as change-over contact0
Type of electrical connection of main circuitBolt connection
Motor drive integratedNo
Rated voltage220 - 690V
With switched-off indicatorNo
Overload release current setting1.4 - 2A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz120kA
Integrated earth fault protectionNo
Adjustment range short-term delayed short-circuit release- - -A
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes
Motor drive optionalYes
Adjustment range undelayed short-circuit release20 - 20A
Suitable for DIN rail (top hat rail) mountingNo
With under voltage releaseNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067629R1 | XT2L 160 TMD 2-20 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles

3

Number of auxiliary contacts as normally closed contact

0

Type of control element

Toggle

Number of auxiliary contacts as normally open contact

0

Degree of protection (IP)

IP20

Position of connection for main current circuit

Front side

Rated permanent current Iu

160A

Number of auxiliary contacts as change-over contact

0

Type of electrical connection of main circuit

Bolt connection

Motor drive integrated

Rated voltage

220 .. 690V

With switched-off indicator

Overload release current setting

1.4 .. 2A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

120kA

Integrated earth fault protection

Adjustment range short-term delayed short-circuit release

- .. -A

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Motor drive optional

Adjustment range undelayed short-circuit release

20 .. 20A

Suitable for DIN rail (top hat rail) mounting

With under voltage release

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.