Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Overload release current setting3.5 - 5A
Type of electrical connection of main circuitBolt connection
With switched-off indicatorNo
Number of auxiliary contacts as change-over contact0
With under voltage releaseNo
Degree of protection (IP)IP20
Adjustment range short-term delayed short-circuit release- - -A
Adjustment range undelayed short-circuit release50 - 50A
Rated voltage220 - 690V
Rated permanent current Iu5A
Position of connection for main current circuitFront side
Number of poles3
Complete device with protection unitYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz120kA
Motor drive integratedNo
Integrated earth fault protectionNo
Motor drive optionalYes
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalYes
Type of control elementRocker lever
Suitable for DIN rail (top hat rail) mountingNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067633R1 | XT2L 160 TMD 5-50 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage control systems
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Overload release current setting

3.5 .. 5A

Type of electrical connection of main circuit

Bolt connection

With switched-off indicator

Number of auxiliary contacts as change-over contact

0

With under voltage release

Degree of protection (IP)

IP20

Adjustment range short-term delayed short-circuit release

- .. -A

Adjustment range undelayed short-circuit release

50 .. 50A

Rated voltage

220 .. 690V

Rated permanent current Iu

5A

Position of connection for main current circuit

Front side

Number of poles

3

Complete device with protection unit

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

120kA

Motor drive integrated

Integrated earth fault protection

Motor drive optional

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Type of control element

Rocker lever

Suitable for DIN rail (top hat rail) mounting