Technical specifications

Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as change-over contact0
Number of poles4
Type of control elementToggle
Rated permanent current Iu160A
Position of connection for main current circuitFront side
Motor drive integratedNo
Overload release current setting1.4 - 2A
Rated voltage220 - 690V
Degree of protection (IP)IP20
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
With switched-off indicatorNo
Adjustment range undelayed short-circuit release20 - 20A
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes
Adjustment range short-term delayed short-circuit release- - -A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz120kA
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionNo
Motor drive optionalYes
With under voltage releaseNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067650R1 | XT2L 160 TMD 2-20 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as change-over contact

0

Number of poles

4

Type of control element

Toggle

Rated permanent current Iu

160A

Position of connection for main current circuit

Front side

Motor drive integrated

Overload release current setting

1.4 .. 2A

Rated voltage

220 .. 690V

Degree of protection (IP)

IP20

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

With switched-off indicator

Adjustment range undelayed short-circuit release

20 .. 20A

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Adjustment range short-term delayed short-circuit release

- .. -A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

120kA

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

Motor drive optional

With under voltage release