Technical specifications

Adjustment range short-term delayed short-circuit release- - -A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Overload release current setting1.75 - 2.5A
Integrated earth fault protectionNo
Rated voltage220 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Type of electrical connection of main circuitBolt connection
Rated permanent current Iu160A
Adjustment range undelayed short-circuit release25.0 - 25.0A
Position of connection for main current circuitFront side
Device constructionBuilt-in device fixed built-in technique
Type of control elementToggle
Complete device with protection unitYes
Number of poles3
Suitable for DIN rail (top hat rail) mountingNo
Degree of protection (IP)IP20
With switched-off indicatorNo
DIN rail (top hat rail) mounting optionalYes
Motor drive integratedNo
With under voltage releaseNo
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067674R1 | XT2V 160 TMD 2,5-25 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release

- .. -A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Overload release current setting

1.75 .. 2.5A

Integrated earth fault protection

Rated voltage

220 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Type of electrical connection of main circuit

Bolt connection

Rated permanent current Iu

160A

Adjustment range undelayed short-circuit release

25.0 .. 25.0A

Position of connection for main current circuit

Front side

Device construction

Built-in device fixed built-in technique

Type of control element

Toggle

Complete device with protection unit

Number of poles

3

Suitable for DIN rail (top hat rail) mounting

Degree of protection (IP)

IP20

With switched-off indicator

DIN rail (top hat rail) mounting optional

Motor drive integrated

With under voltage release

Motor drive optional

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.