Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of poles3
Rated permanent current Iu160A
Number of auxiliary contacts as change-over contact0
Overload release current setting1.75 - 2.5A
Type of control elementToggle
With switched-off indicatorNo
Degree of protection (IP)IP20
Position of connection for main current circuitFront side
Rated voltage220 - 690V
Motor drive integratedNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Type of electrical connection of main circuitBolt connection
Adjustment range short-term delayed short-circuit release- - -A
Motor drive optionalYes
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalYes
Suitable for DIN rail (top hat rail) mountingNo
Complete device with protection unitYes
With under voltage releaseNo
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release25.0 - 25.0A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067674R1 | XT2V 160 TMD 2,5-25 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of poles

3

Rated permanent current Iu

160A

Number of auxiliary contacts as change-over contact

0

Overload release current setting

1.75 .. 2.5A

Type of control element

Toggle

With switched-off indicator

Degree of protection (IP)

IP20

Position of connection for main current circuit

Front side

Rated voltage

220 .. 690V

Motor drive integrated

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Type of electrical connection of main circuit

Bolt connection

Adjustment range short-term delayed short-circuit release

- .. -A

Motor drive optional

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Suitable for DIN rail (top hat rail) mounting

Complete device with protection unit

With under voltage release

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

25.0 .. 25.0A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.