Technical specifications

Number of auxiliary contacts as normally open contact0
Number of poles3
Rated permanent current Iu160A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Overload release current setting2.24 - 3.2A
Integrated earth fault protectionNo
Type of control elementToggle
Adjustment range undelayed short-circuit release32.0 - 32.0A
Suitable for DIN rail (top hat rail) mountingNo
Rated voltage220 - 690V
Adjustment range short-term delayed short-circuit release- - -A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Motor drive integratedNo
Type of electrical connection of main circuitBolt connection
Position of connection for main current circuitFront side
With switched-off indicatorNo
Degree of protection (IP)IP20
Device constructionBuilt-in device fixed built-in technique
Motor drive optionalYes
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes
With under voltage releaseNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067675R1 | XT2V 160 TMD 3,2-32 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of poles

3

Rated permanent current Iu

160A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Overload release current setting

2.24 .. 3.2A

Integrated earth fault protection

Type of control element

Toggle

Adjustment range undelayed short-circuit release

32.0 .. 32.0A

Suitable for DIN rail (top hat rail) mounting

Rated voltage

220 .. 690V

Adjustment range short-term delayed short-circuit release

- .. -A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Motor drive integrated

Type of electrical connection of main circuit

Bolt connection

Position of connection for main current circuit

Front side

With switched-off indicator

Degree of protection (IP)

IP20

Device construction

Built-in device fixed built-in technique

Motor drive optional

DIN rail (top hat rail) mounting optional

Complete device with protection unit

With under voltage release

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.