Technical specifications

Number of auxiliary contacts as normally open contact0
Number of poles3
Overload release current setting17.5 - 25A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Rated voltage220 - 690V
Rated permanent current Iu160A
Degree of protection (IP)IP20
Position of connection for main current circuitFront side
With switched-off indicatorNo
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release300 - 300A
Motor drive integratedNo
Adjustment range short-term delayed short-circuit release- - -A
Type of control elementToggle
Type of electrical connection of main circuitBolt connection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
With under voltage releaseNo
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalYes
Motor drive optionalYes
Device constructionBuilt-in device fixed built-in technique
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067684R1 | XT2V 160 TMD 25-300 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of poles

3

Overload release current setting

17.5 .. 25A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Rated voltage

220 .. 690V

Rated permanent current Iu

160A

Degree of protection (IP)

IP20

Position of connection for main current circuit

Front side

With switched-off indicator

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

300 .. 300A

Motor drive integrated

Adjustment range short-term delayed short-circuit release

- .. -A

Type of control element

Toggle

Type of electrical connection of main circuit

Bolt connection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

With under voltage release

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Motor drive optional

Device construction

Built-in device fixed built-in technique

Complete device with protection unit