Technical specifications

Adjustment range short-term delayed short-circuit release- - -A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Rated permanent current Iu160A
DIN rail (top hat rail) mounting optionalYes
Number of poles3
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
Type of control elementToggle
Complete device with protection unitYes
Motor drive integratedNo
Motor drive optionalYes
Overload release current setting22.4 - 32A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Integrated earth fault protectionNo
Position of connection for main current circuitFront side
Adjustment range undelayed short-circuit release320 - 320A
Rated voltage220 - 690V
Type of electrical connection of main circuitBolt connection
With under voltage releaseNo
With switched-off indicatorNo
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067685R1 | XT2V 160 TMD 32-320 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release

- .. -A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Rated permanent current Iu

160A

DIN rail (top hat rail) mounting optional

Number of poles

3

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

Type of control element

Toggle

Complete device with protection unit

Motor drive integrated

Motor drive optional

Overload release current setting

22.4 .. 32A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Integrated earth fault protection

Position of connection for main current circuit

Front side

Adjustment range undelayed short-circuit release

320 .. 320A

Rated voltage

220 .. 690V

Type of electrical connection of main circuit

Bolt connection

With under voltage release

With switched-off indicator

Degree of protection (IP)

IP20