  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as change-over contact0
Position of connection for main current circuitFront side
Rated permanent current Iu160A
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Degree of protection (IP)IP20
Rated voltage220 - 690V
Number of poles4
Motor drive integratedNo
Overload release current setting5.6 - 8A
Adjustment range short-term delayed short-circuit release- - -A
Type of electrical connection of main circuitBolt connection
Integrated earth fault protectionNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Adjustment range undelayed short-circuit release80 - 80A
With switched-off indicatorNo
Type of control elementToggle
Suitable for DIN rail (top hat rail) mountingNo
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalYes
Motor drive optionalYes
With under voltage releaseNo
Device constructionBuilt-in device fixed built-in technique
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067700R1 | XT2V 160 TMD 8-80 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as change-over contact

0

Position of connection for main current circuit

Front side

Rated permanent current Iu

160A

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Degree of protection (IP)

IP20

Rated voltage

220 .. 690V

Number of poles

4

Motor drive integrated

Overload release current setting

5.6 .. 8A

Adjustment range short-term delayed short-circuit release

- .. -A

Type of electrical connection of main circuit

Bolt connection

Integrated earth fault protection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Adjustment range undelayed short-circuit release

80 .. 80A

With switched-off indicator

Type of control element

Toggle

Suitable for DIN rail (top hat rail) mounting

Complete device with protection unit

DIN rail (top hat rail) mounting optional

Motor drive optional

With under voltage release

Device construction

Built-in device fixed built-in technique

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.