Number of poles4
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu160A
Number of auxiliary contacts as normally closed contact0
Position of connection for main current circuitFront side
Motor drive integratedNo
Degree of protection (IP)IP20
Type of electrical connection of main circuitBolt connection
Overload release current setting7.0 - 10A
Rated voltage220 - 690V
Number of auxiliary contacts as change-over contact0
Suitable for DIN rail (top hat rail) mountingNo
Integrated earth fault protectionNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Type of control elementToggle
With under voltage releaseNo
Adjustment range short-term delayed short-circuit release- - -A
Motor drive optionalYes
With switched-off indicatorNo
Adjustment range undelayed short-circuit release100 - 100A
DIN rail (top hat rail) mounting optionalYes
Device constructionBuilt-in device fixed built-in technique
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067701R1 | XT2V 160 TMD 10-100 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles

4

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

160A

Number of auxiliary contacts as normally closed contact

0

Position of connection for main current circuit

Front side

Motor drive integrated

Degree of protection (IP)

IP20

Type of electrical connection of main circuit

Bolt connection

Overload release current setting

7.0 .. 10A

Rated voltage

220 .. 690V

Number of auxiliary contacts as change-over contact

0

Suitable for DIN rail (top hat rail) mounting

Integrated earth fault protection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Type of control element

Toggle

With under voltage release

Adjustment range short-term delayed short-circuit release

- .. -A

Motor drive optional

With switched-off indicator

Adjustment range undelayed short-circuit release

100 .. 100A

DIN rail (top hat rail) mounting optional

Device construction

Built-in device fixed built-in technique

Complete device with protection unit