Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Number of poles3
Rated permanent current Iu160A
Degree of protection (IP)IP20
Rated voltage220 - 690V
Number of auxiliary contacts as change-over contact0
Overload release current setting28.0 - 40A
Type of control elementToggle
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Type of electrical connection of main circuitBolt connection
With switched-off indicatorNo
Integrated earth fault protectionNo
Motor drive optionalYes
Adjustment range short-term delayed short-circuit release- - -A
Suitable for DIN rail (top hat rail) mountingNo
Motor drive integratedNo
Device constructionBuilt-in device fixed built-in technique
Complete device with protection unitYes
Adjustment range undelayed short-circuit release200 - 200A
With under voltage releaseNo
DIN rail (top hat rail) mounting optionalYes
Position of connection for main current circuitFront side
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067720R1 | XT2N 160 TMG 40-200 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Number of poles

3

Rated permanent current Iu

160A

Degree of protection (IP)

IP20

Rated voltage

220 .. 690V

Number of auxiliary contacts as change-over contact

0

Overload release current setting

28.0 .. 40A

Type of control element

Toggle

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Type of electrical connection of main circuit

Bolt connection

With switched-off indicator

Integrated earth fault protection

Motor drive optional

Adjustment range short-term delayed short-circuit release

- .. -A

Suitable for DIN rail (top hat rail) mounting

Motor drive integrated

Device construction

Built-in device fixed built-in technique

Complete device with protection unit

Adjustment range undelayed short-circuit release

200 .. 200A

With under voltage release

DIN rail (top hat rail) mounting optional

Position of connection for main current circuit

Front side

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.