Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact0
Rated permanent current Iu160A
Number of poles3
Overload release current setting35.0 - 50A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Type of electrical connection of main circuitBolt connection
Motor drive integratedNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range short-term delayed short-circuit release- - -A
With switched-off indicatorNo
Integrated earth fault protectionNo
Device constructionBuilt-in device fixed built-in technique
Rated voltage220 - 690V
Type of control elementToggle
Degree of protection (IP)IP20
Adjustment range undelayed short-circuit release200 - 200A
DIN rail (top hat rail) mounting optionalYes
Motor drive optionalYes
Position of connection for main current circuitFront side
With under voltage releaseNo
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067743R1 | XT2S 160 TMG 50-200 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

160A

Number of poles

3

Overload release current setting

35.0 .. 50A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Type of electrical connection of main circuit

Bolt connection

Motor drive integrated

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Suitable for DIN rail (top hat rail) mounting

Adjustment range short-term delayed short-circuit release

- .. -A

With switched-off indicator

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

Rated voltage

220 .. 690V

Type of control element

Toggle

Degree of protection (IP)

IP20

Adjustment range undelayed short-circuit release

200 .. 200A

DIN rail (top hat rail) mounting optional

Motor drive optional

Position of connection for main current circuit

Front side

With under voltage release

Complete device with protection unit

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.