Aleta.hr
Main Product Image

1SDA067860R1 | XT2H 160 EKIP LS/I IN=100A 3P F F

Code: 1530331

ManufacturerABB
Catalog number1SDA067860R1
EAN code8015644017569

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Rated permanent current Iu160A
Overload release current setting40.0 - 100A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Adjustment range short-term delayed short-circuit release100 - 1000A
Type of electrical connection of main circuitBolt connection
Device constructionBuilt-in device fixed built-in technique
With under voltage releaseNo
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalYes
With switched-off indicatorNo
Position of connection for main current circuitFront side
Type of control elementToggle
Motor drive integratedNo
Number of poles3
Integrated earth fault protectionNo
Complete device with protection unitYes
Motor drive optionalYes
Degree of protection (IP)IP20
Rated voltage220 - 690V
Adjustment range undelayed short-circuit release100 - 1000A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067860R1 | XT2H 160 EKIP LS/I IN=100A 3P F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Rated permanent current Iu

160A

Overload release current setting

40.0 .. 100A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Adjustment range short-term delayed short-circuit release

100 .. 1000A

Type of electrical connection of main circuit

Bolt connection

Device construction

Built-in device fixed built-in technique

With under voltage release

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

With switched-off indicator

Position of connection for main current circuit

Front side

Type of control element

Toggle

Motor drive integrated

Number of poles

3

Integrated earth fault protection

Complete device with protection unit

Motor drive optional

Degree of protection (IP)

IP20

Rated voltage

220 .. 690V

Adjustment range undelayed short-circuit release

100 .. 1000A

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.