Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Motor drive integratedNo
With switched-off indicatorNo
Overload release current setting10.0 - 25A
Rated permanent current Iu160A
Number of auxiliary contacts as change-over contact0
Number of poles4
Degree of protection (IP)IP20
Number of auxiliary contacts as normally open contact0
DIN rail (top hat rail) mounting optionalYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Type of control elementToggle
Type of electrical connection of main circuitBolt connection
Position of connection for main current circuitFront side
Rated voltage220 - 690V
Adjustment range undelayed short-circuit release25 - 250A
Adjustment range short-term delayed short-circuit release25 - 250A
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionYes
Motor drive optionalYes
Suitable for DIN rail (top hat rail) mountingNo
With under voltage releaseNo
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067909R1 | XT2H 160 EKIP LSIG IN=25A 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Motor drive integrated

With switched-off indicator

Overload release current setting

10.0 .. 25A

Rated permanent current Iu

160A

Number of auxiliary contacts as change-over contact

0

Number of poles

4

Degree of protection (IP)

IP20

Number of auxiliary contacts as normally open contact

0

DIN rail (top hat rail) mounting optional

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Type of control element

Toggle

Type of electrical connection of main circuit

Bolt connection

Position of connection for main current circuit

Front side

Rated voltage

220 .. 690V

Adjustment range undelayed short-circuit release

25 .. 250A

Adjustment range short-term delayed short-circuit release

25 .. 250A

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

Motor drive optional

Suitable for DIN rail (top hat rail) mounting

With under voltage release

Complete device with protection unit

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.