Technical specifications

Number of auxiliary contacts as change-over contact0
Type of electrical connection of main circuitBolt connection
Overload release current setting40.0 - 100A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz120kA
Rated voltage220 - 690V
Number of auxiliary contacts as normally open contact0
Number of poles3
Integrated earth fault protectionNo
Rated permanent current Iu160A
Number of auxiliary contacts as normally closed contact0
Adjustment range undelayed short-circuit release100 - 1000A
Degree of protection (IP)IP20
Adjustment range short-term delayed short-circuit release100 - 1000A
Suitable for DIN rail (top hat rail) mountingNo
Motor drive integratedNo
Position of connection for main current circuitFront side
With switched-off indicatorNo
Type of control elementToggle
DIN rail (top hat rail) mounting optionalYes
With under voltage releaseNo
Device constructionBuilt-in device fixed built-in technique
Motor drive optionalYes
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067917R1 | XT2L 160 EKIP LS/I IN=100A 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as change-over contact

0

Type of electrical connection of main circuit

Bolt connection

Overload release current setting

40.0 .. 100A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

120kA

Rated voltage

220 .. 690V

Number of auxiliary contacts as normally open contact

0

Number of poles

3

Integrated earth fault protection

Rated permanent current Iu

160A

Number of auxiliary contacts as normally closed contact

0

Adjustment range undelayed short-circuit release

100 .. 1000A

Degree of protection (IP)

IP20

Adjustment range short-term delayed short-circuit release

100 .. 1000A

Suitable for DIN rail (top hat rail) mounting

Motor drive integrated

Position of connection for main current circuit

Front side

With switched-off indicator

Type of control element

Toggle

DIN rail (top hat rail) mounting optional

With under voltage release

Device construction

Built-in device fixed built-in technique

Motor drive optional

Complete device with protection unit