Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Suitable for DIN rail (top hat rail) mountingNo
Motor drive integratedNo
Complete device with protection unitYes
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Rated voltage220 - 690V
Position of connection for main current circuitFront side
With under voltage releaseNo
Rated permanent current Iu160A
Degree of protection (IP)IP20
Overload release current setting10.0 - 25A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz120kA
Integrated earth fault protectionYes
Motor drive optionalYes
With switched-off indicatorNo
Type of control elementToggle
Adjustment range undelayed short-circuit release25 - 250A
Number of auxiliary contacts as change-over contact0
Adjustment range short-term delayed short-circuit release25 - 250A
DIN rail (top hat rail) mounting optionalYes
Number of poles3
Device constructionBuilt-in device fixed built-in technique
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067930R1 | XT2L 160 EKIP LSIG IN=25A 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Suitable for DIN rail (top hat rail) mounting

Motor drive integrated

Complete device with protection unit

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Rated voltage

220 .. 690V

Position of connection for main current circuit

Front side

With under voltage release

Rated permanent current Iu

160A

Degree of protection (IP)

IP20

Overload release current setting

10.0 .. 25A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

120kA

Integrated earth fault protection

Motor drive optional

With switched-off indicator

Type of control element

Toggle

Adjustment range undelayed short-circuit release

25 .. 250A

Number of auxiliary contacts as change-over contact

0

Adjustment range short-term delayed short-circuit release

25 .. 250A

DIN rail (top hat rail) mounting optional

Number of poles

3

Device construction

Built-in device fixed built-in technique

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.