Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Adjustment range short-term delayed short-circuit release63 - 630A
Overload release current setting25.2 - 63A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz120kA
Type of control elementToggle
Type of electrical connection of main circuitBolt connection
Motor drive integratedNo
Rated voltage220 - 690V
Number of poles4
With switched-off indicatorNo
Position of connection for main current circuitFront side
Rated permanent current Iu160A
Degree of protection (IP)IP20
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
Integrated earth fault protectionNo
Adjustment range undelayed short-circuit release63 - 630A
Motor drive optionalYes
With under voltage releaseNo
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067961R1 | XT2L 160 EKIP LSI IN=63A 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Adjustment range short-term delayed short-circuit release

63 .. 630A

Overload release current setting

25.2 .. 63A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

120kA

Type of control element

Toggle

Type of electrical connection of main circuit

Bolt connection

Motor drive integrated

Rated voltage

220 .. 690V

Number of poles

4

With switched-off indicator

Position of connection for main current circuit

Front side

Rated permanent current Iu

160A

Degree of protection (IP)

IP20

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

Integrated earth fault protection

Adjustment range undelayed short-circuit release

63 .. 630A

Motor drive optional

With under voltage release

Complete device with protection unit

DIN rail (top hat rail) mounting optional

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.