Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as change-over contact0
Adjustment range short-term delayed short-circuit release63 - 630A
Adjustment range undelayed short-circuit release63 - 630A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz120kA
Degree of protection (IP)IP20
Type of electrical connection of main circuitBolt connection
Rated voltage220 - 690V
Number of auxiliary contacts as normally closed contact0
Motor drive integratedNo
Position of connection for main current circuitFront side
With switched-off indicatorNo
Overload release current setting25.2 - 63A
Number of auxiliary contacts as normally open contact0
Type of control elementToggle
Rated permanent current Iu160A
Number of poles4
Suitable for DIN rail (top hat rail) mountingNo
Motor drive optionalYes
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes
With under voltage releaseNo
Integrated earth fault protectionYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067967R1 | XT2L 160 EKIP LSIG IN=63A 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as change-over contact

0

Adjustment range short-term delayed short-circuit release

63 .. 630A

Adjustment range undelayed short-circuit release

63 .. 630A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

120kA

Degree of protection (IP)

IP20

Type of electrical connection of main circuit

Bolt connection

Rated voltage

220 .. 690V

Number of auxiliary contacts as normally closed contact

0

Motor drive integrated

Position of connection for main current circuit

Front side

With switched-off indicator

Overload release current setting

25.2 .. 63A

Number of auxiliary contacts as normally open contact

0

Type of control element

Toggle

Rated permanent current Iu

160A

Number of poles

4

Suitable for DIN rail (top hat rail) mounting

Motor drive optional

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Complete device with protection unit

With under voltage release

Integrated earth fault protection

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.