Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
Degree of protection (IP)IP20
Number of poles3
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu160A
Rated voltage220 - 690V
Overload release current setting10.0 - 25A
Position of connection for main current circuitFront side
Integrated earth fault protectionYes
Adjustment range undelayed short-circuit release25 - 250A
Type of control elementToggle
Adjustment range short-term delayed short-circuit release25 - 250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Suitable for DIN rail (top hat rail) mountingNo
With under voltage releaseNo
DIN rail (top hat rail) mounting optionalYes
Motor drive optionalYes
Motor drive integratedNo
Device constructionBuilt-in device fixed built-in technique
With switched-off indicatorNo
Complete device with protection unitYes
Type of electrical connection of main circuitBolt connection
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067987R1 | XT2V 160 EKIP LSIG IN=25A 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

Degree of protection (IP)

IP20

Number of poles

3

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

160A

Rated voltage

220 .. 690V

Overload release current setting

10.0 .. 25A

Position of connection for main current circuit

Front side

Integrated earth fault protection

Adjustment range undelayed short-circuit release

25 .. 250A

Type of control element

Toggle

Adjustment range short-term delayed short-circuit release

25 .. 250A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Suitable for DIN rail (top hat rail) mounting

With under voltage release

DIN rail (top hat rail) mounting optional

Motor drive optional

Motor drive integrated

Device construction

Built-in device fixed built-in technique

With switched-off indicator

Complete device with protection unit

Type of electrical connection of main circuit

Bolt connection

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.