Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Rated permanent current Iu160A
Device constructionBuilt-in device fixed built-in technique
Type of electrical connection of main circuitBolt connection
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release10 - 100A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
DIN rail (top hat rail) mounting optionalYes
Adjustment range short-term delayed short-circuit release10 - 100A
With under voltage releaseNo
Rated voltage220 - 690V
Integrated earth fault protectionNo
Overload release current setting4.0 - 10A
Number of poles4
Position of connection for main current circuitFront side
Type of control elementToggle
With switched-off indicatorNo
Complete device with protection unitYes
Degree of protection (IP)IP20
Motor drive integratedNo
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068016R1 | XT2V 160 EKIP LSI IN=10A 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Rated permanent current Iu

160A

Device construction

Built-in device fixed built-in technique

Type of electrical connection of main circuit

Bolt connection

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

10 .. 100A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

DIN rail (top hat rail) mounting optional

Adjustment range short-term delayed short-circuit release

10 .. 100A

With under voltage release

Rated voltage

220 .. 690V

Integrated earth fault protection

Overload release current setting

4.0 .. 10A

Number of poles

4

Position of connection for main current circuit

Front side

Type of control element

Toggle

With switched-off indicator

Complete device with protection unit

Degree of protection (IP)

IP20

Motor drive integrated

Motor drive optional

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.