Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu160A
Motor drive integratedNo
Degree of protection (IP)IP20
Rated voltage220 - 690V
Overload release current setting25.2 - 63A
Number of poles4
Suitable for DIN rail (top hat rail) mountingNo
With switched-off indicatorNo
Type of electrical connection of main circuitBolt connection
Position of connection for main current circuitFront side
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Motor drive optionalYes
Adjustment range short-term delayed short-circuit release63 - 630A
Integrated earth fault protectionNo
Number of auxiliary contacts as change-over contact0
Adjustment range undelayed short-circuit release63 - 630A
Type of control elementToggle
With under voltage releaseNo
Device constructionBuilt-in device fixed built-in technique
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068018R1 | XT2V 160 EKIP LSI IN=63A 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

160A

Motor drive integrated

Degree of protection (IP)

IP20

Rated voltage

220 .. 690V

Overload release current setting

25.2 .. 63A

Number of poles

4

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

Type of electrical connection of main circuit

Bolt connection

Position of connection for main current circuit

Front side

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Motor drive optional

Adjustment range short-term delayed short-circuit release

63 .. 630A

Integrated earth fault protection

Number of auxiliary contacts as change-over contact

0

Adjustment range undelayed short-circuit release

63 .. 630A

Type of control element

Toggle

With under voltage release

Device construction

Built-in device fixed built-in technique

Complete device with protection unit

DIN rail (top hat rail) mounting optional

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.