Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Adjustment range short-term delayed short-circuit release10 - 100A
Overload release current setting4.0 - 10A
Rated permanent current Iu160A
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalYes
With under voltage releaseNo
With switched-off indicatorNo
Integrated earth fault protectionYes
Number of poles4
Motor drive integratedNo
Complete device with protection unitYes
Adjustment range undelayed short-circuit release10 - 100A
Motor drive optionalYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Type of control elementToggle
Rated voltage220 - 690V
Suitable for DIN rail (top hat rail) mountingNo
Degree of protection (IP)IP20
Type of electrical connection of main circuitBolt connection
Position of connection for main current circuitFront side
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068022R1 | XT2V 160 EKIP LSIG IN=10A 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Adjustment range short-term delayed short-circuit release

10 .. 100A

Overload release current setting

4.0 .. 10A

Rated permanent current Iu

160A

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

With under voltage release

With switched-off indicator

Integrated earth fault protection

Number of poles

4

Motor drive integrated

Complete device with protection unit

Adjustment range undelayed short-circuit release

10 .. 100A

Motor drive optional

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Type of control element

Toggle

Rated voltage

220 .. 690V

Suitable for DIN rail (top hat rail) mounting

Degree of protection (IP)

IP20

Type of electrical connection of main circuit

Bolt connection

Position of connection for main current circuit

Front side

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.