Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release- - -A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Rated permanent current Iu250A
Rated voltage220 - 690V
Adjustment range undelayed short-circuit release630 - 630A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Overload release current setting44.1 - 63A
Type of electrical connection of main circuitBolt connection
Integrated earth fault protectionNo
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalYes
With switched-off indicatorNo
Type of control elementToggle
With under voltage releaseNo
Motor drive integratedNo
Number of poles4
Degree of protection (IP)IP20
Complete device with protection unitYes
Motor drive optionalYes
Position of connection for main current circuitFront side
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068060R1 | XT3N 250 TMD 63-630 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release

- .. -A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Rated permanent current Iu

250A

Rated voltage

220 .. 690V

Adjustment range undelayed short-circuit release

630 .. 630A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Overload release current setting

44.1 .. 63A

Type of electrical connection of main circuit

Bolt connection

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

With switched-off indicator

Type of control element

Toggle

With under voltage release

Motor drive integrated

Number of poles

4

Degree of protection (IP)

IP20

Complete device with protection unit

Motor drive optional

Position of connection for main current circuit

Front side

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.