Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact0
Rated voltage220 - 690V
Type of control elementToggle
Rated permanent current Iu250A
Motor drive integratedNo
Number of poles4
Degree of protection (IP)IP20
Overload release current setting70.0 - 100A
Type of electrical connection of main circuitBolt connection
Position of connection for main current circuitFront side
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally closed contact0
With switched-off indicatorNo
Adjustment range short-term delayed short-circuit release- - -A
Integrated earth fault protectionNo
Motor drive optionalYes
With under voltage releaseNo
Complete device with protection unitYes
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release1000 - 1000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
DIN rail (top hat rail) mounting optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068062R1 | XT3N 250 TMD 100-1000 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Rated voltage

220 .. 690V

Type of control element

Toggle

Rated permanent current Iu

250A

Motor drive integrated

Number of poles

4

Degree of protection (IP)

IP20

Overload release current setting

70.0 .. 100A

Type of electrical connection of main circuit

Bolt connection

Position of connection for main current circuit

Front side

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally closed contact

0

With switched-off indicator

Adjustment range short-term delayed short-circuit release

- .. -A

Integrated earth fault protection

Motor drive optional

With under voltage release

Complete device with protection unit

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

1000 .. 1000A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

DIN rail (top hat rail) mounting optional

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.