Rated permanent current Iu250A
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Motor drive integratedNo
Position of connection for main current circuitFront side
Rated voltage220 - 690V
Number of poles4
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as change-over contact0
Type of control elementToggle
Degree of protection (IP)IP20
With switched-off indicatorNo
Overload release current setting175.0 - 250A
Adjustment range short-term delayed short-circuit release- - -A
Motor drive optionalYes
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
With under voltage releaseNo
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release2500 - 2500A
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068066R1 | XT3N 250 TMD 250-2500 4P F F INN=50%

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu

250A

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Motor drive integrated

Position of connection for main current circuit

Front side

Rated voltage

220 .. 690V

Number of poles

4

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as change-over contact

0

Type of control element

Toggle

Degree of protection (IP)

IP20

With switched-off indicator

Overload release current setting

175.0 .. 250A

Adjustment range short-term delayed short-circuit release

- .. -A

Motor drive optional

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

With under voltage release

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

2500 .. 2500A

DIN rail (top hat rail) mounting optional

Complete device with protection unit