Technical specifications

Degree of protection (IP)IP20
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Rated permanent current Iu250A
Type of electrical connection of main circuitBolt connection
Motor drive integratedNo
Adjustment range undelayed short-circuit release1250 - 1250A
Position of connection for main current circuitFront side
With switched-off indicatorNo
Number of poles4
Number of auxiliary contacts as normally open contact0
Adjustment range short-term delayed short-circuit release- - -A
Overload release current setting87.5 - 125A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Rated voltage220 - 690V
Suitable for DIN rail (top hat rail) mountingNo
Type of control elementToggle
With under voltage releaseNo
Integrated earth fault protectionNo
Motor drive optionalYes
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068067R1 | XT3N 250 TMD 125-1250 4P F F INN=100%

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)

IP20

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Rated permanent current Iu

250A

Type of electrical connection of main circuit

Bolt connection

Motor drive integrated

Adjustment range undelayed short-circuit release

1250 .. 1250A

Position of connection for main current circuit

Front side

With switched-off indicator

Number of poles

4

Number of auxiliary contacts as normally open contact

0

Adjustment range short-term delayed short-circuit release

- .. -A

Overload release current setting

87.5 .. 125A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Rated voltage

220 .. 690V

Suitable for DIN rail (top hat rail) mounting

Type of control element

Toggle

With under voltage release

Integrated earth fault protection

Motor drive optional

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Complete device with protection unit