Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range undelayed short-circuit release300 - 300A
Overload release current setting17.5 - 25A
Number of auxiliary contacts as change-over contact0
Number of poles3
Rated voltage220 - 690V
Degree of protection (IP)IP20
Motor drive integratedNo
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu160A
Type of control elementToggle
Type of electrical connection of main circuitBolt connection
Position of connection for main current circuitFront side
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Adjustment range short-term delayed short-circuit release- - -A
With switched-off indicatorNo
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionNo
With under voltage releaseNo
Motor drive optionalYes
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068081R1 | XT4N 160 TMD 25-300 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range undelayed short-circuit release

300 .. 300A

Overload release current setting

17.5 .. 25A

Number of auxiliary contacts as change-over contact

0

Number of poles

3

Rated voltage

220 .. 690V

Degree of protection (IP)

IP20

Motor drive integrated

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

160A

Type of control element

Toggle

Type of electrical connection of main circuit

Bolt connection

Position of connection for main current circuit

Front side

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Adjustment range short-term delayed short-circuit release

- .. -A

With switched-off indicator

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

With under voltage release

Motor drive optional

DIN rail (top hat rail) mounting optional

Complete device with protection unit

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.