Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Type of control elementToggle
Type of electrical connection of main circuitBolt connection
Overload release current setting17.5 - 25A
With switched-off indicatorNo
Rated voltage220 - 690V
Number of auxiliary contacts as normally closed contact0
Position of connection for main current circuitFront side
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Number of auxiliary contacts as normally open contact0
Number of poles4
Suitable for DIN rail (top hat rail) mountingNo
With under voltage releaseNo
Motor drive integratedNo
Motor drive optionalYes
Integrated earth fault protectionNo
Degree of protection (IP)IP20
Adjustment range undelayed short-circuit release300 - 300A
Adjustment range short-term delayed short-circuit release- - -A
Number of auxiliary contacts as change-over contact0
Device constructionBuilt-in device fixed built-in technique
Complete device with protection unitYes
Rated permanent current Iu160A
DIN rail (top hat rail) mounting optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068095R1 | XT4N 160 TMD 25-300 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Type of control element

Toggle

Type of electrical connection of main circuit

Bolt connection

Overload release current setting

17.5 .. 25A

With switched-off indicator

Rated voltage

220 .. 690V

Number of auxiliary contacts as normally closed contact

0

Position of connection for main current circuit

Front side

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Number of auxiliary contacts as normally open contact

0

Number of poles

4

Suitable for DIN rail (top hat rail) mounting

With under voltage release

Motor drive integrated

Motor drive optional

Integrated earth fault protection

Degree of protection (IP)

IP20

Adjustment range undelayed short-circuit release

300 .. 300A

Adjustment range short-term delayed short-circuit release

- .. -A

Number of auxiliary contacts as change-over contact

0

Device construction

Built-in device fixed built-in technique

Complete device with protection unit

Rated permanent current Iu

160A

DIN rail (top hat rail) mounting optional

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.