Aleta.hr
Main Product Image

1SDA068099R1 | XT4N 160 TMA 63-630 4P F F

Code: 1530524

ManufacturerABB
Catalog number1SDA068099R1
EAN code8015644019921

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release- - -A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu160A
Suitable for DIN rail (top hat rail) mountingNo
Overload release current setting44.1 - 63A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Type of electrical connection of main circuitBolt connection
Rated voltage220 - 690V
Integrated earth fault protectionNo
With switched-off indicatorNo
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalYes
With under voltage releaseNo
Number of poles4
Adjustment range undelayed short-circuit release315 - 630A
Position of connection for main current circuitFront side
Type of control elementToggle
Degree of protection (IP)IP20
Motor drive integratedNo
Motor drive optionalYes
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068099R1 | XT4N 160 TMA 63-630 4P F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release

- .. -A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

160A

Suitable for DIN rail (top hat rail) mounting

Overload release current setting

44.1 .. 63A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Type of electrical connection of main circuit

Bolt connection

Rated voltage

220 .. 690V

Integrated earth fault protection

With switched-off indicator

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

With under voltage release

Number of poles

4

Adjustment range undelayed short-circuit release

315 .. 630A

Position of connection for main current circuit

Front side

Type of control element

Toggle

Degree of protection (IP)

IP20

Motor drive integrated

Motor drive optional

Complete device with protection unit