1SDA068123R1 | XT4N 160 EKIP LS/I IN=63A 3P F F

Code: 1530548

ManufacturerABB
Catalog number1SDA068123R1
EAN code8015644020002

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Integrated earth fault protectionNo
Rated permanent current Iu160A
Overload release current setting25.2 - 63A
Rated voltage220 - 690V
Adjustment range undelayed short-circuit release63 - 630A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Type of electrical connection of main circuitBolt connection
Position of connection for main current circuitFront side
Complete device with protection unitYes
Adjustment range short-term delayed short-circuit release63 - 630A
Device constructionBuilt-in device fixed built-in technique
Degree of protection (IP)IP20
With under voltage releaseNo
Number of poles3
DIN rail (top hat rail) mounting optionalYes
Suitable for DIN rail (top hat rail) mountingNo
With switched-off indicatorNo
Type of control elementToggle
Motor drive optionalYes
Motor drive integratedNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068123R1 | XT4N 160 EKIP LS/I IN=63A 3P F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Integrated earth fault protection

Rated permanent current Iu

160A

Overload release current setting

25.2 .. 63A

Rated voltage

220 .. 690V

Adjustment range undelayed short-circuit release

63 .. 630A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Type of electrical connection of main circuit

Bolt connection

Position of connection for main current circuit

Front side

Complete device with protection unit

Adjustment range short-term delayed short-circuit release

63 .. 630A

Device construction

Built-in device fixed built-in technique

Degree of protection (IP)

IP20

With under voltage release

Number of poles

3

DIN rail (top hat rail) mounting optional

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

Type of control element

Toggle

Motor drive optional

Motor drive integrated

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.