Aleta.hr
Main Product Image

1SDA068134R1 | XT4N 160 EKIP LSI IN=100A 3P F F

Code: 1530559

ManufacturerABB
Catalog number1SDA068134R1
EAN code8015644695996

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Rated permanent current Iu160A
Suitable for DIN rail (top hat rail) mountingNo
Position of connection for main current circuitFront side
Motor drive optionalYes
Degree of protection (IP)IP20
Rated voltage220 - 690V
Type of electrical connection of main circuitBolt connection
Integrated earth fault protectionNo
Overload release current setting40.0 - 100A
Adjustment range undelayed short-circuit release100 - 1000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Type of control elementToggle
Complete device with protection unitYes
Motor drive integratedNo
Device constructionBuilt-in device fixed built-in technique
Number of poles3
DIN rail (top hat rail) mounting optionalYes
With switched-off indicatorNo
Adjustment range short-term delayed short-circuit release100 - 1000A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068134R1 | XT4N 160 EKIP LSI IN=100A 3P F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Rated permanent current Iu

160A

Suitable for DIN rail (top hat rail) mounting

Position of connection for main current circuit

Front side

Motor drive optional

Degree of protection (IP)

IP20

Rated voltage

220 .. 690V

Type of electrical connection of main circuit

Bolt connection

Integrated earth fault protection

Overload release current setting

40.0 .. 100A

Adjustment range undelayed short-circuit release

100 .. 1000A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Type of control element

Toggle

Complete device with protection unit

Motor drive integrated

Device construction

Built-in device fixed built-in technique

Number of poles

3

DIN rail (top hat rail) mounting optional

With switched-off indicator

Adjustment range short-term delayed short-circuit release

100 .. 1000A

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.