Technical specifications

Degree of protection (IP)IP20
Overload release current setting16.0 - 40A
Rated voltage220 - 690V
Rated permanent current Iu160A
Number of auxiliary contacts as normally closed contact0
Motor drive integratedNo
Number of poles3
Position of connection for main current circuitFront side
Number of auxiliary contacts as change-over contact0
With under voltage releaseNo
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalYes
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device fixed built-in technique
Type of electrical connection of main circuitBolt connection
Adjustment range undelayed short-circuit release40 - 400A
Motor drive optionalYes
Integrated earth fault protectionYes
Type of control elementToggle
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
With switched-off indicatorNo
Number of auxiliary contacts as normally open contact0
Adjustment range short-term delayed short-circuit release40 - 400A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068137R1 | XT4N 160 EKIP LSIG IN=40A 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)

IP20

Overload release current setting

16.0 .. 40A

Rated voltage

220 .. 690V

Rated permanent current Iu

160A

Number of auxiliary contacts as normally closed contact

0

Motor drive integrated

Number of poles

3

Position of connection for main current circuit

Front side

Number of auxiliary contacts as change-over contact

0

With under voltage release

Complete device with protection unit

DIN rail (top hat rail) mounting optional

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

Type of electrical connection of main circuit

Bolt connection

Adjustment range undelayed short-circuit release

40 .. 400A

Motor drive optional

Integrated earth fault protection

Type of control element

Toggle

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

With switched-off indicator

Number of auxiliary contacts as normally open contact

0

Adjustment range short-term delayed short-circuit release

40 .. 400A