Aleta.hr
Main Product Image

1SDA068142R1 | XT4N 160 EKIP LS/I IN=40A 4P F F

Code: 1530567

ManufacturerABB
Catalog number1SDA068142R1
EAN code8015644696030

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Rated permanent current Iu160A
Integrated earth fault protectionNo
Rated voltage220 - 690V
Type of electrical connection of main circuitBolt connection
With under voltage releaseNo
Overload release current setting16.0 - 40A
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release40 - 400A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Suitable for DIN rail (top hat rail) mountingNo
With switched-off indicatorNo
Adjustment range short-term delayed short-circuit release40 - 400A
Number of poles4
Complete device with protection unitYes
Position of connection for main current circuitFront side
Motor drive optionalYes
Type of control elementToggle
Motor drive integratedNo
Degree of protection (IP)IP20
DIN rail (top hat rail) mounting optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068142R1 | XT4N 160 EKIP LS/I IN=40A 4P F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Rated permanent current Iu

160A

Integrated earth fault protection

Rated voltage

220 .. 690V

Type of electrical connection of main circuit

Bolt connection

With under voltage release

Overload release current setting

16.0 .. 40A

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

40 .. 400A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

Adjustment range short-term delayed short-circuit release

40 .. 400A

Number of poles

4

Complete device with protection unit

Position of connection for main current circuit

Front side

Motor drive optional

Type of control element

Toggle

Motor drive integrated

Degree of protection (IP)

IP20

DIN rail (top hat rail) mounting optional

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.