Aleta.hr
Main Product Image

1SDA068163R1 | XT2N 160 3P F F

Code: 1530587

ManufacturerABB
Catalog number1SDA068163R1
EAN code8015644696139

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Overload release current setting- - -A
Adjustment range undelayed short-circuit release- - -A
Adjustment range short-term delayed short-circuit release- - -A
Rated voltage220 - 690V
Number of auxiliary contacts as normally closed contact0
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally open contact0
Device constructionBuilt-in device fixed built-in technique
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as change-over contact0
With switched-off indicatorNo
Motor drive integratedNo
Motor drive optionalYes
With integrated under voltage releaseNo
Type of control elementToggle
Degree of protection (IP)IP20
DIN rail (top hat rail) mounting optionalYes
Number of poles3
Complete device with protection unitNo
Position of connection for main current circuitFront side
Rated permanent current Iu160A
Integrated earth fault protectionNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068163R1 | XT2N 160 3P F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Overload release current setting

- .. -A

Adjustment range undelayed short-circuit release

- .. -A

Adjustment range short-term delayed short-circuit release

- .. -A

Rated voltage

220 .. 690V

Number of auxiliary contacts as normally closed contact

0

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally open contact

0

Device construction

Built-in device fixed built-in technique

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as change-over contact

0

With switched-off indicator

Motor drive integrated

Motor drive optional

With integrated under voltage release

Type of control element

Toggle

Degree of protection (IP)

IP20

DIN rail (top hat rail) mounting optional

Number of poles

3

Complete device with protection unit

Position of connection for main current circuit

Front side

Rated permanent current Iu

160A

Integrated earth fault protection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.