Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release- - -A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Overload release current setting70.0 - 100A
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release1000 - 1000A
Rated permanent current Iu250A
Number of poles3
Type of electrical connection of main circuitBolt connection
Integrated earth fault protectionNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalYes
Rated voltage220 - 690V
With switched-off indicatorNo
Type of control elementToggle
Complete device with protection unitYes
Motor drive optionalYes
Degree of protection (IP)IP20
Motor drive integratedNo
With under voltage releaseNo
Position of connection for main current circuitFront side
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068217R1 | XT3S 250 TMD 100-1000 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release

- .. -A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Overload release current setting

70.0 .. 100A

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

1000 .. 1000A

Rated permanent current Iu

250A

Number of poles

3

Type of electrical connection of main circuit

Bolt connection

Integrated earth fault protection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Rated voltage

220 .. 690V

With switched-off indicator

Type of control element

Toggle

Complete device with protection unit

Motor drive optional

Degree of protection (IP)

IP20

Motor drive integrated

With under voltage release

Position of connection for main current circuit

Front side

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.