Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Position of connection for main current circuitFront side
Degree of protection (IP)IP20
Number of auxiliary contacts as normally closed contact0
Overload release current setting44.1 - 63A
Number of poles4
Rated permanent current Iu250A
With switched-off indicatorNo
Rated voltage220 - 690V
Type of control elementToggle
Motor drive integratedNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Adjustment range short-term delayed short-circuit release- - -A
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release630 - 630A
Number of auxiliary contacts as change-over contact0
Type of electrical connection of main circuitBolt connection
Device constructionBuilt-in device fixed built-in technique
With under voltage releaseNo
Motor drive optionalYes
Number of auxiliary contacts as normally open contact0
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068222R1 | XT3S 250 TMD 63-630 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Position of connection for main current circuit

Front side

Degree of protection (IP)

IP20

Number of auxiliary contacts as normally closed contact

0

Overload release current setting

44.1 .. 63A

Number of poles

4

Rated permanent current Iu

250A

With switched-off indicator

Rated voltage

220 .. 690V

Type of control element

Toggle

Motor drive integrated

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Adjustment range short-term delayed short-circuit release

- .. -A

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

630 .. 630A

Number of auxiliary contacts as change-over contact

0

Type of electrical connection of main circuit

Bolt connection

Device construction

Built-in device fixed built-in technique

With under voltage release

Motor drive optional

Number of auxiliary contacts as normally open contact

0

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Complete device with protection unit

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.