Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Overload release current setting87.5 - 125A
Position of connection for main current circuitFront side
Number of auxiliary contacts as normally open contact0
Motor drive integratedNo
With under voltage releaseNo
Adjustment range short-term delayed short-circuit release- - -A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Type of electrical connection of main circuitBolt connection
Rated voltage220 - 690V
Integrated earth fault protectionNo
Adjustment range undelayed short-circuit release1250 - 1250A
Suitable for DIN rail (top hat rail) mountingNo
Rated permanent current Iu250A
Device constructionBuilt-in device fixed built-in technique
Number of poles4
Type of control elementToggle
With switched-off indicatorNo
Motor drive optionalYes
Degree of protection (IP)IP20
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068225R1 | XT3S 250 TMD 125-1250 4P F F INN=50%

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Overload release current setting

87.5 .. 125A

Position of connection for main current circuit

Front side

Number of auxiliary contacts as normally open contact

0

Motor drive integrated

With under voltage release

Adjustment range short-term delayed short-circuit release

- .. -A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Type of electrical connection of main circuit

Bolt connection

Rated voltage

220 .. 690V

Integrated earth fault protection

Adjustment range undelayed short-circuit release

1250 .. 1250A

Suitable for DIN rail (top hat rail) mounting

Rated permanent current Iu

250A

Device construction

Built-in device fixed built-in technique

Number of poles

4

Type of control element

Toggle

With switched-off indicator

Motor drive optional

Degree of protection (IP)

IP20

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Complete device with protection unit

DIN rail (top hat rail) mounting optional

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.