Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated voltage220 - 690V
Rated permanent current Iu250A
Position of connection for main current circuitFront side
Overload release current setting175.0 - 250A
Degree of protection (IP)IP20
Number of auxiliary contacts as normally closed contact0
Type of control elementToggle
Type of electrical connection of main circuitBolt connection
Motor drive integratedNo
Number of poles3
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
With switched-off indicatorNo
Adjustment range undelayed short-circuit release750 - 750A
Adjustment range short-term delayed short-circuit release- - -A
Complete device with protection unitYes
Motor drive optionalYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Device constructionBuilt-in device fixed built-in technique
With under voltage releaseNo
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalYes
Suitable for DIN rail (top hat rail) mountingNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068257R1 | XT3N 250 TMG 250-750 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

220 .. 690V

Rated permanent current Iu

250A

Position of connection for main current circuit

Front side

Overload release current setting

175.0 .. 250A

Degree of protection (IP)

IP20

Number of auxiliary contacts as normally closed contact

0

Type of control element

Toggle

Type of electrical connection of main circuit

Bolt connection

Motor drive integrated

Number of poles

3

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

With switched-off indicator

Adjustment range undelayed short-circuit release

750 .. 750A

Adjustment range short-term delayed short-circuit release

- .. -A

Complete device with protection unit

Motor drive optional

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Device construction

Built-in device fixed built-in technique

With under voltage release

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Suitable for DIN rail (top hat rail) mounting

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.