Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release- - -A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Rated permanent current Iu250A
Rated voltage220 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
With under voltage releaseNo
Integrated earth fault protectionNo
Type of electrical connection of main circuitBolt connection
Suitable for DIN rail (top hat rail) mountingNo
Number of poles4
With switched-off indicatorNo
Complete device with protection unitYes
Motor drive optionalYes
Degree of protection (IP)IP20
Motor drive integratedNo
Adjustment range undelayed short-circuit release600 - 600A
DIN rail (top hat rail) mounting optionalYes
Overload release current setting140.0 - 200A
Device constructionBuilt-in device fixed built-in technique
Position of connection for main current circuitFront side
Type of control elementToggle
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068263R1 | XT3N 250 TMG 200-600 4P F F INN=100%

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release

- .. -A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Rated permanent current Iu

250A

Rated voltage

220 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

With under voltage release

Integrated earth fault protection

Type of electrical connection of main circuit

Bolt connection

Suitable for DIN rail (top hat rail) mounting

Number of poles

4

With switched-off indicator

Complete device with protection unit

Motor drive optional

Degree of protection (IP)

IP20

Motor drive integrated

Adjustment range undelayed short-circuit release

600 .. 600A

DIN rail (top hat rail) mounting optional

Overload release current setting

140.0 .. 200A

Device construction

Built-in device fixed built-in technique

Position of connection for main current circuit

Front side

Type of control element

Toggle

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.