Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of poles3
Rated permanent current Iu250A
Overload release current setting140.0 - 200A
Number of auxiliary contacts as normally open contact0
Type of electrical connection of main circuitBolt connection
Degree of protection (IP)IP20
Position of connection for main current circuitFront side
Rated voltage220 - 690V
Motor drive integratedNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Number of auxiliary contacts as change-over contact0
Type of control elementToggle
With switched-off indicatorNo
Integrated earth fault protectionNo
Motor drive optionalYes
Adjustment range undelayed short-circuit release600 - 600A
With under voltage releaseNo
Adjustment range short-term delayed short-circuit release- - -A
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device fixed built-in technique
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068270R1 | XT3S 250 TMG 200-600 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of poles

3

Rated permanent current Iu

250A

Overload release current setting

140.0 .. 200A

Number of auxiliary contacts as normally open contact

0

Type of electrical connection of main circuit

Bolt connection

Degree of protection (IP)

IP20

Position of connection for main current circuit

Front side

Rated voltage

220 .. 690V

Motor drive integrated

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Number of auxiliary contacts as change-over contact

0

Type of control element

Toggle

With switched-off indicator

Integrated earth fault protection

Motor drive optional

Adjustment range undelayed short-circuit release

600 .. 600A

With under voltage release

Adjustment range short-term delayed short-circuit release

- .. -A

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

Complete device with protection unit

DIN rail (top hat rail) mounting optional

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.