Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)IP20
Motor drive integratedNo
Rated voltage220 - 690V
Number of auxiliary contacts as normally closed contact0
Overload release current setting44.1 - 63A
Number of poles4
Position of connection for main current circuitFront side
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu250A
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as change-over contact0
With switched-off indicatorNo
Suitable for DIN rail (top hat rail) mountingNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Integrated earth fault protectionNo
Adjustment range undelayed short-circuit release400 - 400A
Type of control elementToggle
Motor drive optionalYes
With under voltage releaseNo
Adjustment range short-term delayed short-circuit release- - -A
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes
Device constructionBuilt-in device fixed built-in technique
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068272R1 | XT3S 250 TMG 63-400 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)

IP20

Motor drive integrated

Rated voltage

220 .. 690V

Number of auxiliary contacts as normally closed contact

0

Overload release current setting

44.1 .. 63A

Number of poles

4

Position of connection for main current circuit

Front side

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

250A

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as change-over contact

0

With switched-off indicator

Suitable for DIN rail (top hat rail) mounting

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Integrated earth fault protection

Adjustment range undelayed short-circuit release

400 .. 400A

Type of control element

Toggle

Motor drive optional

With under voltage release

Adjustment range short-term delayed short-circuit release

- .. -A

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Device construction

Built-in device fixed built-in technique

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.