Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)IP20
Motor drive integratedNo
Number of auxiliary contacts as change-over contact0
Rated voltage220 - 690V
Rated permanent current Iu250A
Type of control elementToggle
Number of auxiliary contacts as normally closed contact0
With switched-off indicatorNo
Type of electrical connection of main circuitBolt connection
Number of poles3
Overload release current setting- - -A
Position of connection for main current circuitFront side
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Number of auxiliary contacts as normally open contact0
Integrated earth fault protectionNo
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release600 - 1200A
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes
Motor drive optionalYes
Device constructionBuilt-in device fixed built-in technique
Adjustment range short-term delayed short-circuit release- - -A
With under voltage releaseNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068279R1 | XT3S 250 MA 100 IM=600...1200 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)

IP20

Motor drive integrated

Number of auxiliary contacts as change-over contact

0

Rated voltage

220 .. 690V

Rated permanent current Iu

250A

Type of control element

Toggle

Number of auxiliary contacts as normally closed contact

0

With switched-off indicator

Type of electrical connection of main circuit

Bolt connection

Number of poles

3

Overload release current setting

- .. -A

Position of connection for main current circuit

Front side

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Number of auxiliary contacts as normally open contact

0

Integrated earth fault protection

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

600 .. 1200A

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Motor drive optional

Device construction

Built-in device fixed built-in technique

Adjustment range short-term delayed short-circuit release

- .. -A

With under voltage release

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.