  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as change-over contact0
Overload release current setting- - -A
Number of poles3
Rated permanent current Iu250A
Number of auxiliary contacts as normally open contact0
Rated voltage220 - 690V
Number of auxiliary contacts as normally closed contact0
With switched-off indicatorNo
Adjustment range undelayed short-circuit release750 - 1500A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Adjustment range short-term delayed short-circuit release- - -A
Type of electrical connection of main circuitBolt connection
Position of connection for main current circuitFront side
Type of control elementToggle
Degree of protection (IP)IP20
Motor drive integratedNo
Integrated earth fault protectionNo
Suitable for DIN rail (top hat rail) mountingNo
With under voltage releaseNo
DIN rail (top hat rail) mounting optionalYes
Motor drive optionalYes
Complete device with protection unitYes
Device constructionBuilt-in device fixed built-in technique
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068280R1 | XT3S 250 MA125 IM=750...1500 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as change-over contact

0

Overload release current setting

- .. -A

Number of poles

3

Rated permanent current Iu

250A

Number of auxiliary contacts as normally open contact

0

Rated voltage

220 .. 690V

Number of auxiliary contacts as normally closed contact

0

With switched-off indicator

Adjustment range undelayed short-circuit release

750 .. 1500A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Adjustment range short-term delayed short-circuit release

- .. -A

Type of electrical connection of main circuit

Bolt connection

Position of connection for main current circuit

Front side

Type of control element

Toggle

Degree of protection (IP)

IP20

Motor drive integrated

Integrated earth fault protection

Suitable for DIN rail (top hat rail) mounting

With under voltage release

DIN rail (top hat rail) mounting optional

Motor drive optional

Complete device with protection unit

Device construction

Built-in device fixed built-in technique