Technical specifications

Adjustment range short-term delayed short-circuit release- - -A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Rated permanent current Iu160A
Integrated earth fault protectionNo
Adjustment range undelayed short-circuit release300 - 300A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Device constructionBuilt-in device fixed built-in technique
Type of electrical connection of main circuitBolt connection
DIN rail (top hat rail) mounting optionalYes
Overload release current setting17.5 - 25A
With under voltage releaseNo
Suitable for DIN rail (top hat rail) mountingNo
Type of control elementToggle
With switched-off indicatorNo
Number of poles3
Complete device with protection unitYes
Motor drive integratedNo
Rated voltage220 - 690V
Motor drive optionalYes
Degree of protection (IP)IP20
Position of connection for main current circuitFront side
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068301R1 | XT4S 160 TMD 25-300 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release

- .. -A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Rated permanent current Iu

160A

Integrated earth fault protection

Adjustment range undelayed short-circuit release

300 .. 300A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Device construction

Built-in device fixed built-in technique

Type of electrical connection of main circuit

Bolt connection

DIN rail (top hat rail) mounting optional

Overload release current setting

17.5 .. 25A

With under voltage release

Suitable for DIN rail (top hat rail) mounting

Type of control element

Toggle

With switched-off indicator

Number of poles

3

Complete device with protection unit

Motor drive integrated

Rated voltage

220 .. 690V

Motor drive optional

Degree of protection (IP)

IP20

Position of connection for main current circuit

Front side

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.