  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as change-over contact0
Rated permanent current Iu160A
Number of poles4
Overload release current setting11.2 - 16A
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
With under voltage releaseNo
Motor drive optionalYes
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release300 - 300A
Complete device with protection unitYes
Integrated earth fault protectionNo
Type of electrical connection of main circuitBolt connection
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalYes
Type of control elementToggle
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Adjustment range short-term delayed short-circuit release- - -A
With switched-off indicatorNo
Motor drive integratedNo
Position of connection for main current circuitFront side
Degree of protection (IP)IP20
Rated voltage220 - 690V
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068313R1 | XT4S 160 TMD 16-300 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as change-over contact

0

Rated permanent current Iu

160A

Number of poles

4

Overload release current setting

11.2 .. 16A

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

With under voltage release

Motor drive optional

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

300 .. 300A

Complete device with protection unit

Integrated earth fault protection

Type of electrical connection of main circuit

Bolt connection

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Type of control element

Toggle

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Adjustment range short-term delayed short-circuit release

- .. -A

With switched-off indicator

Motor drive integrated

Position of connection for main current circuit

Front side

Degree of protection (IP)

IP20

Rated voltage

220 .. 690V

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.