Technical specifications

Degree of protection (IP)IP20
Rated voltage220 - 690V
Position of connection for main current circuitFront side
Number of auxiliary contacts as normally closed contact0
Overload release current setting56.0 - 80A
Rated permanent current Iu160A
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as change-over contact0
Number of poles4
Number of auxiliary contacts as normally open contact0
Motor drive integratedNo
Integrated earth fault protectionNo
Suitable for DIN rail (top hat rail) mountingNo
Complete device with protection unitYes
Adjustment range short-term delayed short-circuit release- - -A
Adjustment range undelayed short-circuit release400 - 800A
With under voltage releaseNo
Motor drive optionalYes
Device constructionBuilt-in device fixed built-in technique
With switched-off indicatorNo
Type of control elementToggle
DIN rail (top hat rail) mounting optionalYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068320R1 | XT4S 160 TMA 80-800 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)

IP20

Rated voltage

220 .. 690V

Position of connection for main current circuit

Front side

Number of auxiliary contacts as normally closed contact

0

Overload release current setting

56.0 .. 80A

Rated permanent current Iu

160A

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as change-over contact

0

Number of poles

4

Number of auxiliary contacts as normally open contact

0

Motor drive integrated

Integrated earth fault protection

Suitable for DIN rail (top hat rail) mounting

Complete device with protection unit

Adjustment range short-term delayed short-circuit release

- .. -A

Adjustment range undelayed short-circuit release

400 .. 800A

With under voltage release

Motor drive optional

Device construction

Built-in device fixed built-in technique

With switched-off indicator

Type of control element

Toggle

DIN rail (top hat rail) mounting optional

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.