Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release- - -A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Rated voltage220 - 690V
Adjustment range undelayed short-circuit release1125 - 2250A
Rated permanent current Iu250A
Overload release current setting157.5 - 225A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device fixed built-in technique
With switched-off indicatorNo
Complete device with protection unitYes
Motor drive integratedNo
Degree of protection (IP)IP20
Position of connection for main current circuitFront side
With under voltage releaseNo
Number of poles3
Motor drive optionalYes
Type of control elementToggle
DIN rail (top hat rail) mounting optionalYes
Type of electrical connection of main circuitBolt connection
Integrated earth fault protectionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068344R1 | XT4H 250 TMA 225-2250 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release

- .. -A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Rated voltage

220 .. 690V

Adjustment range undelayed short-circuit release

1125 .. 2250A

Rated permanent current Iu

250A

Overload release current setting

157.5 .. 225A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

With switched-off indicator

Complete device with protection unit

Motor drive integrated

Degree of protection (IP)

IP20

Position of connection for main current circuit

Front side

With under voltage release

Number of poles

3

Motor drive optional

Type of control element

Toggle

DIN rail (top hat rail) mounting optional

Type of electrical connection of main circuit

Bolt connection

Integrated earth fault protection

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.