Aleta.hr
Main Product Image

1SDA068348R1 | XT4H 160 TMD 25-300 4P F F

Code: 1530746

ManufacturerABB
Catalog number1SDA068348R1
EAN code8015644022549

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release- - -A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Rated voltage220 - 690V
Rated permanent current Iu160A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Device constructionBuilt-in device fixed built-in technique
Overload release current setting17.5 - 25A
Adjustment range undelayed short-circuit release300 - 300A
Number of poles4
Type of control elementToggle
Integrated earth fault protectionNo
With under voltage releaseNo
Motor drive integratedNo
Motor drive optionalYes
Type of electrical connection of main circuitBolt connection
Position of connection for main current circuitFront side
DIN rail (top hat rail) mounting optionalYes
Suitable for DIN rail (top hat rail) mountingNo
Complete device with protection unitYes
Degree of protection (IP)IP20
With switched-off indicatorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068348R1 | XT4H 160 TMD 25-300 4P F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release

- .. -A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Rated voltage

220 .. 690V

Rated permanent current Iu

160A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Device construction

Built-in device fixed built-in technique

Overload release current setting

17.5 .. 25A

Adjustment range undelayed short-circuit release

300 .. 300A

Number of poles

4

Type of control element

Toggle

Integrated earth fault protection

With under voltage release

Motor drive integrated

Motor drive optional

Type of electrical connection of main circuit

Bolt connection

Position of connection for main current circuit

Front side

DIN rail (top hat rail) mounting optional

Suitable for DIN rail (top hat rail) mounting

Complete device with protection unit

Degree of protection (IP)

IP20

With switched-off indicator