Technical specifications

Number of poles4
Number of auxiliary contacts as normally open contact0
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as normally closed contact0
Suitable for DIN rail (top hat rail) mountingNo
Motor drive integratedNo
Type of control elementToggle
Overload release current setting17.5 - 25A
Position of connection for main current circuitFront side
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Rated voltage220 - 690V
Adjustment range undelayed short-circuit release300 - 300A
Rated permanent current Iu160A
With switched-off indicatorNo
Adjustment range short-term delayed short-circuit release- - -A
Number of auxiliary contacts as change-over contact0
Degree of protection (IP)IP20
Complete device with protection unitYes
Motor drive optionalYes
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalYes
With under voltage releaseNo
Device constructionBuilt-in device fixed built-in technique
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068348R1 | XT4H 160 TMD 25-300 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles

4

Number of auxiliary contacts as normally open contact

0

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as normally closed contact

0

Suitable for DIN rail (top hat rail) mounting

Motor drive integrated

Type of control element

Toggle

Overload release current setting

17.5 .. 25A

Position of connection for main current circuit

Front side

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Rated voltage

220 .. 690V

Adjustment range undelayed short-circuit release

300 .. 300A

Rated permanent current Iu

160A

With switched-off indicator

Adjustment range short-term delayed short-circuit release

- .. -A

Number of auxiliary contacts as change-over contact

0

Degree of protection (IP)

IP20

Complete device with protection unit

Motor drive optional

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

With under voltage release

Device construction

Built-in device fixed built-in technique

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.